Application note: Chemical doses, pH/chlorine targets, run times and maintenance intervals are determined according to the product label, the measured water values, the usage class and local requirements. Numerical examples do not in themselves constitute application instructions. Chemicals must never be mixed with one another; each must be added to the water separately and as stated on its label. Electrical work, pressurized equipment and pool draining must be carried out under the supervision of a qualified specialist in accordance with local standards.
The most common mistake pool owners make in pool maintenance is assuming that water clarity comes down to pH and chlorine readings alone. In reality, even clear water with a pH of 7.4 can be chemically aggressive or scale forming. The measure commonly used to assess whether pool water will deposit scale on surfaces or, remaining undersaturated with respect to calcium carbonate, will instead attack joints, metal parts and heat pump exchangers is the Langelier Saturation Index (LSI). When the LSI value is not kept within the -0.3 to +0.3 range, problems such as corrosion in metal exchangers, hardening and discolouration of the liner surface, and cloudiness in the water become more likely. These effects depend on the size and duration of the deviation. At Sermed Havuz we place water balance on a measurable footing using the LSI approach.
The LSI value is the combined result of the water's pH, temperature, calcium hardness, alkalinity and TDS values. When the LSI falls below -0.3, the water becomes undersaturated with respect to calcium carbonate and takes on an aggressive character; the risk of dissolution of joint grouts, corrosion of metal parts and damage to the heat pump exchanger increases. When the LSI rises above +0.3, the water deposits scale, which can clump the filter sand and form a white crust on surfaces. The -0.3 to +0.3 band is the commonly recommended balance range.
Water is a solvent; it tends to take from the surfaces it touches any mineral with which it is not saturated, and to precipitate that mineral when oversaturated. Balance begins with measuring and managing this behaviour.
01. The Saturation Chemistry of Water: Aggressive Corrosion vs. Scale Crust
What can be seen when the calcium carbonate balance in pool water is disturbed:
- The danger of a negative LSI (< -0.3): The water is undersaturated with respect to calcium carbonate; it can dissolve joint grout, contribute to corrosion of metal surfaces including stainless steel, increase the risk of damage to the heat pump exchanger, and contribute to hardening of the liner surface over time.
- The danger of a positive LSI (> +0.3): The water is saturated with calcium carbonate and precipitates the excess. A rough white scale crust can form on the pool walls, and the filter sand can clump and harden over time.
02. The LSI Formula: A Balancing Algorithm of 5 Key Factors
The LSI is commonly calculated with the following approximate formula:
LSI = pH + TF (Temperature Factor) + CF (Calcium Factor) + AF (Alkalinity Factor) - TDS constant (typically 12.1)
- pH: Kept in the 7.2 – 7.6 range; because it enters the formula directly, it is the fastest acting variable.
- Temperature factor (TF): As the water cools, the LSI falls (cold water is more aggressive in character); as the water warms, the LSI rises and the tendency to deposit scale increases.
- Calcium hardness (CF): The commonly recommended range is 200–250 ppm CaCO₃; the acceptable range can vary with the pool type and the lining.
- Total alkalinity (AF): Generally recommended in the 80–120 ppm band, where it acts as a pH buffer.
03. LSI Value Ranges and Equipment Damage Table
| LSI score range | Condition of the water | Effect on the pool shell and liner | Effect on pipework and the heater |
|---|---|---|---|
| < -0.50 | Markedly aggressive / corrosive | The liner surface can harden and joint grout can dissolve | Increased risk of corrosion in the heat pump exchanger and rusting of metal fittings |
| -0.30 to -0.01 | Slightly aggressive | Tolerable lower limit | Slight tendency to attack metals |
| 0.00 (perfect balance) | Balanced water | The chemical load on the liner and lining remains at its lowest level | The most favourable condition for equipment service life |
| +0.01 to +0.30 | Slightly scale forming | Tolerable upper limit | A thin protective calcium film |
| > +0.50 | Markedly scale depositing | White scale crust on surfaces | The filter sand can clump and narrowing of the pipe cross section can occur |
Conclusion: Keeping the LSI balance between -0.3 and +0.3 means managing pool chemistry by measurement rather than guesswork. The service life of the liner and equipment also depends on material quality, UV exposure, intensity of use and the maintenance regime; warranty coverage is subject to the written warranty terms.
Frequently asked questions
How is the LSI balance measured?
The LSI is not measured directly; it is calculated. The pH, calcium hardness, total alkalinity, water temperature and TDS values are measured with a digital photometer or a reliable test kit; when these values are entered into an LSI calculation sheet or app, the index is computed. The accuracy of the result depends entirely on the accuracy of the measurements.
Why does the LSI shift towards corrosion in winter?
As the water temperature falls, the temperature factor becomes smaller and the LSI shifts negative; for this reason, keeping calcium hardness and pH in the upper part of the recommended range going into winter is considered on the basis of the measurement results.
How is the LSI balanced in saltwater pools?
In salt electrolysis pools, the water salinity is generally kept within the range stated by the manufacturer (a frequently used target is 3,000–3,500 ppm; what governs is the unit's own rated value). Because high TDS changes the constant used in the formula, it must be included in the LSI calculation. An automatic pH dosing pump helps keep the pH more stable; however, it does not fix the LSI on its own, and calcium and alkalinity must also be monitored separately.
How is calcium hardness increased?
A calcium chloride based hardness increaser is added to the water at the dosage and by the method stated on its label, with filtration running, to raise hardness into the target range (commonly recommended at 200–250 ppm). The dose must be calculated from the measured current hardness and the pool volume, and the product must not be mixed with other chemicals.