Pool models, construction conditions and care to help you plan your project.
In this guide 4
Selection note: The Fiplus shell is a 20 mm F-Stone fiber cement panel; the galvanized steel external cross leg is a component separate from the shell. Maldiv and Bora have special alloy steel casings. Shell warranty periods are 25 years for Fiplus and 10 years for Maldiv/Bora; coverage and exclusions depend on the conditions set out in the written warranty document. Dimensions, performance and document compliance must be verified separately for the selected product and project.
The detail that most impresses those planning a villa pool when they look at architectural renderings is the overflow pool with weirs on all four sides; however, an overflow pool requires a balance tank (reservoir) on the order of roughly 10 to 15 percent of the pool volume, together with perimeter overflow channels, grilles and automatic level balancing equipment. These additional works increase excavation and construction costs; the rate of increase varies with plot conditions, tank volume and the detailing chosen, and is determined by a project-specific survey. In regions with heavy rainfall, surface water entering the overflow channel and reaching the balance tank can also bring an extra maintenance burden. Skimmer systems, with their compact structure that requires no balance tank, preserve garden space and simplify the construction budget.
The overflow pool is a solution preferred in hotels and heavily used commercial facilities in terms of surface cleaning; in the garden of a detached villa, however, balance tank and channel maintenance means an additional operating burden.
01. The Hidden Cost of an Overflow Pool: Balance Tank, Overflow Channel and Evaporation Loss
The technical difficulties faced by those who opt for an overflow pool are as follows:
- Extra Balance Tank Excavation and Waterproofing: As an example planning calculation, in a 45 m³ pool, taking 10 to 15 percent of the volume as the basis, a balance tank with a useful volume of roughly 4.5 to 7 m³ comes into play; the tank volume is determined by hydraulic calculation according to the weir flow rate, the channel volume and the user load. In a small garden this means additional excavation, concrete and waterproofing.
- Overflow of the Balance Tank in Heavy Rain: In heavy rainfall, rainwater coming from the overflow channel can raise the balance tank level rapidly; excess water can disrupt the operation of the automatic fill and level control equipment and alter the chemical balance of the water by diluting it. For this reason, drainage around the channel and excess water discharge from the tank must be designed in.
- Algae Growth Inside the Channel: Because the channels beneath the overflow grilles remain constantly wet and without light, they are conducive to biofilm and algae growth; the grilles must be removed and the channel brushed regularly.
- High Heat and Water Loss: Because water flows continuously through wide channels and the moving surface area increases, evaporation and heat loss are higher than in a skimmer system; the difference depends on wind, temperature and the operating regime and cannot be expressed with a single verified percentage figure.
02. Sermed Pools Skimmer Architecture: Direct Suction, Zero Balance Tank and Low Consumption
The skimmer technology that is standard in the Fiplus, Maldiv and Bora models provides the following advantages:
- Direct Closed-Circuit Suction: Water is drawn to the pump directly from the skimmer throat and the bottom suction strainer. Because there is no open balance tank in between, the water is not affected by contamination from a tank surface or by surface water ingress.
- Less Excavation and Zero Channels: No overflow channel or balance tank is built in the garden; once the pool shell is complete, site work is largely finished. The excavation volume saved is equal to the size of the tank and channels forgone.
- Flawless Waterline Aesthetics: In a skimmer pool the water level sits a few centimeters below the coping stone; with slim-throat skimmer detailing, a mirror effect close to that of an overflow pool can be achieved.
- Heat and Chemical Savings: Because there is no open channel flow, the moving surface and evaporation are reduced; this generally provides an advantage in terms of heating energy and the loss of volatile chemicals. The actual saving depends on the use of a pool cover, the target water temperature and climate data.
03. Comparative Engineering Table for Skimmer vs. Overflow Systems
| Assessment Parameter | Skimmer System (Sermed Standard) | Conventional Overflow System | Budget and Operating Impact for the Villa Owner |
|---|---|---|---|
| Need for a Balance Tank | NONE (closed-circuit hydraulics) | YES (a reinforced concrete tank sized by hydraulic calculation is mandatory) | Because the tank and channel items disappear, excavation and construction costs fall; the proportion varies by project |
| Overflow Channel and Grille | NONE (clean coping finish) | YES (a grille line around the pool) | Aims to reduce the workload of cleaning beneath the grilles |
| Resistance to Batumi Rainfall | More protected (the level is controlled by a suitably sized excess water discharge) | More sensitive (rainwater from the channel can raise the tank) | Makes it easier to maintain the water balance after heavy rainfall |
| Evaporation and Heat Loss | Low (calm surface) | Higher (continuous flow in the channels and surface contact) | Provides savings in heating energy; the amount depends on the climate and cover use |
| Initial Investment Cost | Rational and compact | Higher (extra pump, channels, tank) | Allows the budget to be shifted to the pool's comfort equipment |
Conclusion: In villa projects an overflow system brings a clear construction and maintenance burden in exchange for the visual gain. In most villa applications a skimmer system offers water management that is more economical and easier to operate.
Frequently asked questions
Why does a skimmer pool system that requires no balance tank need 30% less excavation area in Batumi villa gardens?
Giving a single fixed percentage would not be accurate; the saving depends entirely on the volume of the works forgone. An overflow pool requires a deep reinforced concrete balance tank with a useful volume corresponding to roughly 10 to 15 percent of the pool volume, plus a perimeter channel structure. In a skimmer pool, because water is drawn directly from the pool shell, this tank excavation and channel concrete work disappear entirely; the excavation and concrete volume in the garden is reduced by exactly these items.
How is dirt on the water surface cleaned in a skimmer pool?
The clean water delivered through the nozzles carries the dust and leaves on the surface toward the skimmer mouth on the surface current; the skimmer basket catches the coarse debris, while fine particles reach the filter. Setting the nozzle directions correctly determines the efficiency of surface skimming.
How many centimeters should the water level be in a skimmer pool?
The ideal water level should be in the middle region of the height of the skimmer mouth, roughly between 1/2 and 2/3; this way the pump skims the dirt on the surface steadily without drawing air. If the level drops below the skimmer mouth, the pump can draw air.
Can a skimmer pool be used in boutique hotels?
Yes. A skimmer pool with twin skimmers and a circulation pump of sufficient flow rate can be used in boutique hotels and apart-hotel facilities. The appropriate number of skimmers, the circulation flow rate and the turnover time must be calculated according to the facility's peak user load; hygiene and disinfection requirements must be verified against the legislation in force in the country where the business is located and with the opinion of the competent authority.

Fiplus ↗
Maldiv ↗
Bora ↗