← BlogCare & troubleshooting

How to Remedy Calcium Hunger in Black Sea Mains Water

In a liner-lined pool there is no cement grout to dissolve; however, the heat pump heat exchanger, the pump's mechanical seal and the stainless steel parts are in direct contact with the water, and calcium-hungry water can accelerate corrosion on these metal surfaces.

6 min
How to Remedy Calcium Hunger in Black Sea Mains Water
Sermed Havuz photo · illustrative
Sermed Havuz technical team

Pool models, construction conditions and care to help you plan your project.

In this guide 4
  1. 01The Aggressiveness of Soft Water: Calcium Hunger and Metal Corrosion
  2. 02Calcium Chloride Calculation and Safe Application Method
  3. 03Soft Raw Water vs. Balanced Pool Water Parameter Table
  4. 04Frequently Asked Questions

Application note: Chemical doses, pH/chlorine targets, run times and maintenance intervals are determined according to the product label, measured water values, the usage class and local requirements. The water quality values in this article are not verified local measurement data but example assumptions for planning purposes. Chemicals must never be mixed with one another; electrical work, pressurized equipment and pool draining operations must be carried out under specialist supervision.

While those filling pools in limescale-prone regions complain that the water is excessively hard, in high-rainfall basins fed from higher altitudes the problem is often the opposite: the water is very soft. The calcium hardness of your own mains water can only be known by measuring it; it varies by supply area and by season. For the water in a swimming pool to remain in corrosion balance, common practice recommends keeping calcium hardness in the 200-250 ppm CaCO₃ band. Water significantly below this value is "hungry" for calcium; in order to reach saturation it tends to dissolve the metal surfaces it contacts (pump shaft, stainless steel ladder, heat pump heat exchanger) and cement-based joints. Below we explain the protocol for raising hardness with calcium chloride (CaCl₂) on a measurement-based footing.

Soft mains water can be poor in calcium hardness; as an example assumption, in water measuring 50-90 ppm, the water tends to erode joints and metal surfaces in order to come into balance. At the first water fill, calcium chloride (77% CaCl₂) is added in an amount calculated according to the measured hardness value, bringing the hardness into the recommended 200-250 ppm band. As an indication of magnitude, a requirement on the order of roughly 1.5-2 kg per 10 m³ of water may arise; the exact amount is calculated with the formula below.

Soft spring waters that are ideal for drinking can behave corrosively from the point of view of the pool's mechanical installation. If the water is not given the calcium it needs, its search for balance is satisfied at the expense of equipment surfaces.

01. The Aggressiveness of Soft Water: Calcium Hunger and Metal Corrosion

The damage that water with low calcium hardness can cause in a pool:

  • Damage to the Heat Pump Heat Exchanger: Unbalanced, corrosive water can erode the titanium or copper heat exchanger surfaces of the heat pump over time and lead to leakage. Whether such damage is covered under warranty depends on the manufacturer's written warranty conditions and on documented maintenance of the water chemistry.
  • The Liner Membrane Losing Its Flexibility: Unbalanced water can contribute to the gradual leaching of the plasticizers that give PVC liner its flexibility; the membrane hardens and its service life is shortened.
  • Surface Rusting on Stainless Steel: Surface rust spots can begin to appear on AISI 304 and, depending on conditions, AISI 316 grade stainless steel ladders and flanges.

02. Calcium Chloride Calculation and Safe Application Method

The water's calcium hunger is remedied with the following practical calculation:

Required CaCl₂ (kg) = [Target Hardness (200 ppm) - Current Hardness (ppm)] × Pool Volume (m³) × 0.0013

  1. Application Step:
    Example calculation: in a 45 m³ pool, if the measured hardness is 70 ppm, the shortfall is 130 ppm.
    130 × 45 × 0.0013 = approximately 7.6 kg of 77% calcium chloride
    The coefficient varies with the purity of the product; the final amount must be confirmed against the dosage table on the product label.
  2. Critical Safety Rule:
    When calcium chloride mixes with water it produces an exothermic (heat-releasing) reaction. The water heats up as the chemical is added to the bucket; for this reason it must be added a little at a time and poured into the pool only once it has fully dissolved in the plastic bucket. It must never be thrown directly into the skimmer and must never be mixed in the same bucket with any other chemical.

03. Soft Raw Water vs. Balanced Pool Water Parameter Table

The values in the left-hand column are not verified regional measurements but example planning assumptions for soft water; your own water must always be tested.

ParameterExample Soft Raw Water (Assumption)Ideal Balance Range for a PoolDifference and Risk
Calcium Hardness50 - 80 ppm (Very Low)200 - 250 ppmAggressive water erodes equipment surfaces
Total Alkalinity40 - 60 ppm (Low)80 - 120 ppmpH drops or rises abruptly
pH Level6.8 - 7.1 (Slightly Acidic)7.2 - 7.6Corrosion and skin irritation
LSI Score-0.80 (Corrosive Zone, example)-0.30 to +0.30Risk of corrosion and leakage in the installation

Conclusion: Measuring and balancing calcium hardness at the first fill significantly reduces the long-term corrosion risk to the pool's mechanical installation.

Frequently asked questions

Why does calcium matter in a prefabricated liner pool when there is no reinforced concrete?

In a liner-lined pool there is no cement grout to dissolve; however, the heat pump heat exchanger, the pump's mechanical seal and the stainless steel parts are in direct contact with the water, and calcium-hungry water can accelerate corrosion on these metal surfaces.

Does calcium chloride make the water cloudy?

If it is thoroughly dissolved in a bucket and poured into the pool while the filter is running, any temporary cloudiness generally clears within a few hours; if the cloudiness is persistent, the pH and alkalinity should be measured again.

Is calcium hardness lost through evaporation?

No; when water evaporates the calcium remains in the pool and its concentration increases. Calcium is only reduced through backwashing and water discharge; measuring it 1-2 times per season is sufficient for most applications.

Does rainwater lower calcium hardness?

Yes; heavy rainfall adds water with a low mineral content to the pool and dilutes the calcium concentration. Overflow and discharge also cause losses; for this reason the hardness test should be repeated after rainy periods.

Frequently asked questions →
Sermed Havuz technical team

Source: Sermed Havuz technical materials

Request a consultation →

Your next summer starts here.

Share your location and a photo of your space. We’ll help you choose a pool and cover.